BIT Parameters | |||||
---|---|---|---|---|---|
Hex | Decimal | Coil | Name | Clear Name | Set Name |
0000 | 0 | 10001 | Alarm1 | Off | On |
0000 | 0 | 10005 | Alarm2 | Off | On |
0000 | 0 | 10009 | Alarm1 Output | Relay Off | Relay On |
0000 | 0 | 10010 | Alarm2 Output | Relay Off | Relay On |
0000 | 0 | 10012 | HB Alarm Output | HB Off | HB On |
0000 | 0 | 10013 | Alarm1 (same as 10001) | Off | On |
0000 | 0 | 10014 | Alarm2 (same as 10002) | Off | On |
0000 | 0 | 10016 | HB Alarm Output (same as 10012) | HB Off | HB On |
Read Only Parameters (EU) | |||||
---|---|---|---|---|---|
Hex | Decimal | Coil | Name | Description | Display |
02E4 | 740 | 31001 | Process value (PV) | 0 to 10000 (0.00 to 100.00%FS | |
08CA | 2250 | 31002 | Currently used set value (SV) | 0 to 10000 (0.00 to 100.00%FS) | |
FA19 | -1511 | 31003 | Currently used deviation (DV) | -10000 to 10000 (-100.00 to 100.00%FS) | |
283C | 10300 | 31004 | MV (output 1) | -300 to 10300 (-3.00 to 103.00%) | OUT1 |
FED4 | -300 | 31005 | MV (output 2) | -300 to 10300 (-3.00 to 103.00%) | OUT2 |
0001 | 1 | 31006 | Station No. | 0 to 255 | STno |
0000 | 0 | 31007 | Alarm status | (refer to Section 7.4.) | |
0000 | 0 | 31008 | Input/main unit abnormal status | (refer to Section 7.4.) | |
0000 | 0 | 31009 | Ramp/soak current running position | 0 to 17 (refer to Section 7.4.) | STAT |
0000 | 0 | 31010 | Heater current | 0 to 5000.0 to 50.0A | CT |
0000 | 0 | 31011 | Timer 1 current count | 0 to 9999 (0 to 9999 sec) | TM-1 |
0000 | 0 | 31012 | Timer 2 current count | 0 to 9999 (0 to 9999 sec) | TM-2 |
0000 | 0 | 31015 | DI action status | (refer to Section 7.4.) |
Read/Write Parameters (EU) | |||||
---|---|---|---|---|---|
Hex | Decimal | Coil | Name | Description | Display |
0000 | 0 | 41001 | Non-volatile memory write-in | ||
0000 | 0 | 41002 | PID/FUZZY/SELF selection | 0:PID control,1:FUZZYcontrol,2:SELF tuning control | CTrL |
08CA | 2250 | 41003 | SV value set on face panel | 0 to 10000 | |
0000 | 0 | 41004 | Control RUN/standby | 0: Invalidate standby (RUN),1:Validate standby | STby |
0000 | 0 | 41005 | Auto tuning command | AT | |
0037 | 55 | 41006 | P | 0 to 9999 (0.0 to 999.9%) | P |
035A | 858 | 41007 | I | 0 to 32000 (0 to 3200.0) sec | i |
00A5 | 165 | 41008 | D | 0 to 9999 (0.0 to 999.9) sec | D |
000A | 10 | 41009 | Hysteresis range at two-position control | 0 to 5000 (0.00 to 50.00%FS) | HyS |
000A | 10 | 41010 | COOL | 0 to 1000 (0.0 to 100.0) | CooL |
0000 | 0 | 41011 | Dead band | -5000 to 5000 (-50.00 to +50.00) | db |
00FB | 251 | 41012 | Anti-reset windup | 0 to 10000 (0.00 to 100.00%) | Ar |
0000 | 0 | 41013 | Output convergence value | -10000 to 10000 (-100.00 to 100.00%) | bAL |
0000 | 0 | 41014 | PV shift | -1000 to 1000 (-10.00 to 10.00%FS) | PVOF |
0000 | 0 | 41015 | SV offset | -5000 to 5000 (-50.00 to 50.00%FS) | SVOF |
0003 | 3 | 41016 | Input type code | 0 to 16 | P-n2 |
0001 | 1 | 41017 | Temperature unit | 0:degC 1:degF | P-F |
0140 | 320 | 41018 | Input scale lower limit | -1999 to 9999 | P-SL |
1D60 | 7520 | 41019 | Input scale upper limit | -1999 to 9999 | P-SU |
0001 | 1 | 41020 | Decimal point place | 0 to 2 | P-dP |
000A | 10 | 41022 | Input filter time constant | 0 to 9000 (0.0 to 900.0 sec) | P-dF |
0001 | 1 | 41023 | RCJ yes/no | 0: Disable RCJ,1: Enable RCJ | rCJ |
0000 | 0 | 41024 | MV limit kind | 0 to 15 | PCUT |
FED4 | -300 | 41025 | Output 1 lower limit | -300 to 10300 (-3.00 to 103.00%) | PLC1 |
283C | 10300 | 41026 | Output 1 upper limit | -300 to 10300 (-3.00 to 103.00%) | PHC1 |
FED4 | -300 | 41027 | Output 2 lower limit | -300 to 10300 (-3.00 to 103.00%) | PLC2 |
283C | 10300 | 41028 | Output 2 upper limit | -300 to 10300 (-3.00 to 103.00%) | PHC2 |
0140 | 320 | 41031 | Set value (SV) lower limit | 0 to 10000 (0.00 to 100.00%FS) | SV-L |
1D60 | 7520 | 41032 | Set value (SV) upper limit | 0 to 10000 (0.00 to 100.00%FS) | SV-H |
0000 | 0 | 41039 | Heater burnout alarm set value | 0 to 500(0.0 to 50.0A) | Hb |
0000 | 0 | 41040 | Setting lock | 0 to 5 | LoC |
000B | 11 | 41041 | Alarm 1 type | 0 to 34 | ALM1 |
0000 | 0 | 41042 | Alarm 2 type | 0 to 34 | ALM2 |
0005 | 5 | 41044 | Alarm 1 set value or alarm 1 lower limit set value | AL1 or A1-L | |
0000 | 0 | 41045 | Alarm 2 set value or alarm 2 lower limit set value | AL2 or A2-L | |
0005 | 5 | 41047 | Alarm 1 upper limit set value | A1-H | |
0000 | 0 | 41048 | Alarm 2 upper limit set value | A2-H | |
0000 | 0 | 41050 | Alarm 1 hysteresis | 0 to 5000 (0.00 to 50.00%FS) | A1hy |
0000 | 0 | 41051 | Alarm 2 hysteresis | 0 to 5000 (0.00 to 50.00%FS) | A2hy |
0000 | 0 | 41053 | Alarm 1 ON-delay set value | 0 to 9999 (0 to 9999 sec) | dLy1 |
0000 | 0 | 41054 | Alarm 2 ON-delay set value | 0 to 9999 (0 to 9999 sec) | dLy2 |
0BB8 | 3000 | 41057 | Ramp/soak No. 1 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-1 |
0140 | 320 | 41058 | Ramp/soak No. 2 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-2 |
0140 | 320 | 41059 | Ramp/soak No. 3 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-3 |
0140 | 320 | 41060 | Ramp/soak No. 4 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-4 |
0140 | 320 | 41061 | Ramp/soak No. 5 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-5 |
0140 | 320 | 41062 | Ramp/soak No. 6 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-6 |
0140 | 320 | 41063 | Ramp/soak No. 7 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-7 |
0140 | 320 | 41064 | Ramp/soak No. 8 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-8 |
0000 | 0 | 41065 | Ramp/soak No. 1 ramp time | 0 to 59999 (0 to 5999min) | TM1r |
0000 | 0 | 41066 | Ramp/soak No. 1 soak time | 0 to 5999 (0 to 5999 min) | TM1S |
0000 | 0 | 41067 | Ramp/soak No. 2 ramp time | 0 to 5999 (0 to 5999 min) | TM2r |
0000 | 0 | 41068 | Ramp/soak No. 2 soak time | 0 to 5999 (0 to 5999 min) | TM2S |
0000 | 0 | 41069 | Ramp/soak No. 3 ramp time | 0 to 5999 (0 to 5999 min) | TM3r |
0000 | 0 | 41070 | Ramp/soak No. 3 soak time | 0 to 5999 (0 to 5999 min) | TM3S |
0000 | 0 | 41071 | Ramp/soak No. 4 ramp time | 0 to 5999 (0 to 5999 min) | TM4r |
0000 | 0 | 41072 | Ramp/soak No. 4 soak time | 0 to 5999 (0 to 5999 min) | TM4S |
0000 | 0 | 41073 | Ramp/soak No. 5 ramp time | 0 to 5999 (0 to 5999 min) | TM5r |
0000 | 0 | 41074 | Ramp/soak No. 5 soak time | 0 to 5999 (0 to 5999 min) | TM5S |
0000 | 0 | 41075 | Ramp/soak No. 6 ramp time | 0 to 5999 (0 to 5999 min) | TM6r |
0000 | 0 | 41076 | Ramp/soak No. 6 soak time | 0 to 5999 (0 to 5999 min) | TM6S |
0000 | 0 | 41077 | Ramp/soak No. 7 ramp time | 0 to 5999 (0 to 5999 min) | TM7r |
0000 | 0 | 41078 | Ramp/soak No. 7 soak time | 0 to 5999 (0 to 5999 min) | TM7S |
0000 | 0 | 41079 | Ramp/soak No. 8 ramp time | 0 to 5999 (0 to 5999 min) | TM8r |
0000 | 0 | 41080 | Ramp/soak No. 8 soak time | 0 to 5999 (0 to 5999 min) | TM8S |
0000 | 0 | 41081 | Ramp/soak mode | 0 to 15 | MOD |
0000 | 0 | 41082 | Ramp/soak command | ProG | |
0000 | 0 | 41083 | Ramp/soak pattern selection | PTn | |
008C | 140 | 41085 | PV stable range | 0 to 10000(0.00 to 100.00%FS) | SLFb |
0000 | 0 | 41087 | Communication DI action request | (refer to section 7.4.) | |
0000 | 0 | 41088 | Control action type code | 0 to 19 | P-n1 |
0001 | 1 | 41089 | Output proportional cycle (output 1) | 0: Current output type,1 to 150(1 to 150 sec):Relay, SSR drive output type | TC |
001E | 30 | 41090 | Output proportional cycle (output 2) | 1 to 150(1 to 150 sec) | TC2 |
0000 | 0 | 41092 | Alarm 1 option function | 0 to 7 (binary data 000B to 111B) | A1op |
0000 | 0 | 41093 | Alarm 2 option function | 0 to 7 (binary data 000B to 111B) | A2op |
0001 | 1 | 41095 | DI1 action setting | 0 to 12 | di-1 |
0001 | 1 | 41097 | Hysteresis mode setting | 0: off (main unit parameter setting) 1: on (main unit parameter setting) | ONOF |
0000 | 0 | 41099 | User zero adjustment | -5000 to 5000 (-50.00 to 50.00%FS) | ADJ0 |
0000 | 0 | 41100 | User span adjustment | -5000 to 5000 (-50.00 to 50.00%FS) | ADJS |
00F4 | 244 | 41101 | DSP1 (parameter mask designation) | 0 to 255 | dSP1 |
00FF | 255 | 41102 | DSP2 (parameter mask designation) | 0 to 255 | dSP2 |
00E0 | 224 | 41103 | DSP3 (parameter mask designation) | 0 to 255 | dSP3 |
002D | 45 | 41104 | DSP4 (parameter mask designation) | 0 to 255 | dSP4 |
00D4 | 212 | 41105 | DSP5 (parameter mask designation) | 0 to 255 | dSP5 |
0001 | 1 | 41106 | DSP6 (parameter mask designation) | 0 to 255 | dSP6 |
0000 | 0 | 41107 | DSP7 (parameter mask designation) | 0 to 255 | dSP7 |
0000 | 0 | 41108 | DSP8 (parameter mask designation) | 0 to 255 | dSP8 |
0080 | 128 | 41109 | DSP9 (parameter mask designation) | 0 to 255 | dSP9 |
00FF | 255 | 41110 | DSP10 (parameter mask designation) | 0 to 255 | dSP10 |
00FF | 255 | 41111 | DSP11 (parameter mask designation) | 0 to 255 | dSP11 |
005F | 95 | 41112 | DSP12 (parameter mask designation) | 0 to 255 | dSP12 |
007C | 124 | 41113 | DSP13 (parameter mask designation) | 0 to 255 | dSP13 |
Read Only Parameters (Raw) | |||||
---|---|---|---|---|---|
Hex | Decimal | Coil | Name | Description | Display |
0246 | 582 | 30001 | Process value (PV) | 0 to 10000 (0.00 to 100.00%FS | |
0A79 | 2681 | 30002 | Currently used set value (SV) | 0 to 10000 (0.00 to 100.00%FS) | |
F7CC | -2100 | 30003 | Currently used deviation (DV) | -10000 to 10000 (-100.00 to 100.00%FS) | |
283C | 10300 | 30004 | MV (output 1) | -300 to 10300 (-3.00 to 103.00%) | OUT1 |
FED4 | -300 | 30005 | MV (output 2) | -300 to 10300 (-3.00 to 103.00%) | OUT2 |
0001 | 1 | 30006 | Station No. | 0 to 255 | STno |
0000 | 0 | 30007 | Alarm status | (refer to Section 7.4.) | |
0000 | 0 | 30008 | Input/main unit abnormal status | (refer to Section 7.4.) | |
0000 | 0 | 30009 | Ramp/soak current running position | 0 to 17 (refer to Section 7.4.) | STAT |
0000 | 0 | 30010 | Heater current | 0 to 5000.0 to 50.0A | CT |
0000 | 0 | 30011 | Timer 1 current count | 0 to 9999 (0 to 9999 sec) | TM-1 |
0000 | 0 | 30012 | Timer 2 current count | 0 to 9999 (0 to 9999 sec) | TM-2 |
0000 | 0 | 30015 | DI action status | (refer to Section 7.4.) |
Read/Write Parameters (Raw) | |||||
---|---|---|---|---|---|
Hex | Decimal | Coil | Name | Description | Display |
0000 | 0 | 40001 | Non-volatile memory write-in | ||
0000 | 0 | 40002 | PID/FUZZY/SELF selection | 0:PID control,1:FUZZYcontrol,2:SELF tuning control | CTrL |
0A79 | 2681 | 40003 | SV value set on face panel | 0 to 10000 | |
0000 | 0 | 40004 | Control RUN/standby | 0: Invalidate standby (RUN),1:Validate standby | STby |
0000 | 0 | 40005 | Auto tuning command | AT | |
0037 | 55 | 40006 | P | 0 to 9999 (0.0 to 999.9%) | P |
035A | 858 | 40007 | I | 0 to 32000 (0 to 3200.0) sec | i |
00A5 | 165 | 40008 | D | 0 to 9999 (0.0 to 999.9) sec | D |
000E | 14 | 40009 | Hysteresis range at two-position control | 0 to 5000 (0.00 to 50.00%FS) | HyS |
000A | 10 | 40010 | COOL | 0 to 1000 (0.0 to 100.0) | CooL |
0000 | 0 | 40011 | Dead band | -5000 to 5000 (-50.00 to +50.00) | db |
015D | 349 | 40012 | Anti-reset windup | 0 to 10000 (0.00 to 100.00%) | Ar |
0000 | 0 | 40013 | Output convergence value | -10000 to 10000 (-100.00 to 100.00%) | bAL |
0000 | 0 | 40014 | PV shift | -1000 to 1000 (-10.00 to 10.00%FS) | PVOF |
0000 | 0 | 40015 | SV offset | -5000 to 5000 (-50.00 to 50.00%FS) | SVOF |
0003 | 3 | 40016 | Input type code | 0 to 16 | P-n2 |
0001 | 1 | 40017 | Temperature unit | 0:degC 1:degF | P-F |
0140 | 320 | 40018 | Input scale lower limit | -1999 to 9999 | P-SL |
1D60 | 7520 | 40019 | Input scale upper limit | -1999 to 9999 | P-SU |
0001 | 1 | 40020 | Decimal point place | 0 to 2 | P-dP |
000A | 10 | 40022 | Input filter time constant | 0 to 9000 (0.0 to 900.0 sec) | P-dF |
0001 | 1 | 40023 | RCJ yes/no | 0: Disable RCJ,1: Enable RCJ | rCJ |
0000 | 0 | 40024 | MV limit kind | 0 to 15 | PCUT |
FED4 | -300 | 40025 | Output 1 lower limit | -300 to 10300 (-3.00 to 103.00%) | PLC1 |
283C | 10300 | 40026 | Output 1 upper limit | -300 to 10300 (-3.00 to 103.00%) | PHC1 |
FED4 | -300 | 40027 | Output 2 lower limit | -300 to 10300 (-3.00 to 103.00%) | PLC2 |
283C | 10300 | 40028 | Output 2 upper limit | -300 to 10300 (-3.00 to 103.00%) | PHC2 |
0000 | 0 | 40031 | Set value (SV) lower limit | 0 to 10000 (0.00 to 100.00%FS) | SV-L |
2710 | 10000 | 40032 | Set value (SV) upper limit | 0 to 10000 (0.00 to 100.00%FS) | SV-H |
0000 | 0 | 40039 | Heater burnout alarm set value | 0 to 500(0.0 to 50.0A) | Hb |
0000 | 0 | 40040 | Setting lock | 0 to 5 | LoC |
000B | 11 | 40041 | Alarm 1 type | 0 to 34 | ALM1 |
0000 | 0 | 40042 | Alarm 2 type | 0 to 34 | ALM2 |
0007 | 7 | 40044 | Alarm 1 set value or alarm 1 lower limit set value | AL1 or A1-L | |
FE44 | -444 | 40045 | Alarm 2 set value or alarm 2 lower limit set value | AL2 or A2-L | |
0007 | 7 | 40047 | Alarm 1 upper limit set value | A1-H | |
FE44 | -444 | 40048 | Alarm 2 upper limit set value | A2-H | |
0000 | 0 | 40050 | Alarm 1 hysteresis | 0 to 5000 (0.00 to 50.00%FS) | A1hy |
0000 | 0 | 40051 | Alarm 2 hysteresis | 0 to 5000 (0.00 to 50.00%FS) | A2hy |
0000 | 0 | 40053 | Alarm 1 ON-delay set value | 0 to 9999 (0 to 9999 sec) | dLy1 |
0000 | 0 | 40054 | Alarm 2 ON-delay set value | 0 to 9999 (0 to 9999 sec) | dLy2 |
0E8A | 3722 | 40057 | Ramp/soak No. 1 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-1 |
0000 | 0 | 40058 | Ramp/soak No. 2 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-2 |
0000 | 0 | 40059 | Ramp/soak No. 3 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-3 |
0000 | 0 | 40060 | Ramp/soak No. 4 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-4 |
0000 | 0 | 40061 | Ramp/soak No. 5 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-5 |
0000 | 0 | 40062 | Ramp/soak No. 6 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-6 |
0000 | 0 | 40063 | Ramp/soak No. 7 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-7 |
0000 | 0 | 40064 | Ramp/soak No. 8 target value | 0 to 10000 (0.00 to 100.00%FS, within set value limit) | Sv-8 |
0000 | 0 | 40065 | Ramp/soak No. 1 ramp time | 0 to 59999 (0 to 5999min) | TM1r |
0000 | 0 | 40066 | Ramp/soak No. 1 soak time | 0 to 5999 (0 to 5999 min) | TM1S |
0000 | 0 | 40067 | Ramp/soak No. 2 ramp time | 0 to 5999 (0 to 5999 min) | TM2r |
0000 | 0 | 40068 | Ramp/soak No. 2 soak time | 0 to 5999 (0 to 5999 min) | TM2S |
0000 | 0 | 40069 | Ramp/soak No. 3 ramp time | 0 to 5999 (0 to 5999 min) | TM3r |
0000 | 0 | 40070 | Ramp/soak No. 3 soak time | 0 to 5999 (0 to 5999 min) | TM3S |
0000 | 0 | 40071 | Ramp/soak No. 4 ramp time | 0 to 5999 (0 to 5999 min) | TM4r |
0000 | 0 | 40072 | Ramp/soak No. 4 soak time | 0 to 5999 (0 to 5999 min) | TM4S |
0000 | 0 | 40073 | Ramp/soak No. 5 ramp time | 0 to 5999 (0 to 5999 min) | TM5r |
0000 | 0 | 40074 | Ramp/soak No. 5 soak time | 0 to 5999 (0 to 5999 min) | TM5S |
0000 | 0 | 40075 | Ramp/soak No. 6 ramp time | 0 to 5999 (0 to 5999 min) | TM6r |
0000 | 0 | 40076 | Ramp/soak No. 6 soak time | 0 to 5999 (0 to 5999 min) | TM6S |
0000 | 0 | 40077 | Ramp/soak No. 7 ramp time | 0 to 5999 (0 to 5999 min) | TM7r |
0000 | 0 | 40078 | Ramp/soak No. 7 soak time | 0 to 5999 (0 to 5999 min) | TM7S |
0000 | 0 | 40079 | Ramp/soak No. 8 ramp time | 0 to 5999 (0 to 5999 min) | TM8r |
0000 | 0 | 40080 | Ramp/soak No. 8 soak time | 0 to 5999 (0 to 5999 min) | TM8S |
0000 | 0 | 40081 | Ramp/soak mode | 0 to 15 | MOD |
0000 | 0 | 40082 | Ramp/soak command | ProG | |
0000 | 0 | 40083 | Ramp/soak pattern selection | PTn | |
00C2 | 194 | 40085 | PV stable range | 0 to 10000(0.00 to 100.00%FS) | SLFb |
0000 | 0 | 40087 | Communication DI action request | (refer to section 7.4.) | |
0000 | 0 | 40088 | Control action type code | 0 to 19 | P-n1 |
0001 | 1 | 40089 | Output proportional cycle (output 1) | 0: Current output type,1 to 150(1 to 150 sec):Relay, SSR drive output type | TC |
001E | 30 | 40090 | Output proportional cycle (output 2) | 1 to 150(1 to 150 sec) | TC2 |
0000 | 0 | 40092 | Alarm 1 option function | 0 to 7 (binary data 000B to 111B) | A1op |
0000 | 0 | 40093 | Alarm 2 option function | 0 to 7 (binary data 000B to 111B) | A2op |
0001 | 1 | 40095 | DI1 action setting | 0 to 12 | di-1 |
0001 | 1 | 40097 | Hysteresis mode setting | 0: off (main unit parameter setting) 1: on (main unit parameter setting) | ONOF |
0000 | 0 | 40099 | User zero adjustment | -5000 to 5000 (-50.00 to 50.00%FS) | ADJ0 |
0000 | 0 | 40100 | User span adjustment | -5000 to 5000 (-50.00 to 50.00%FS) | ADJS |
00F4 | 244 | 40101 | DSP1 (parameter mask designation) | 0 to 255 | dSP1 |
00FF | 255 | 40102 | DSP2 (parameter mask designation) | 0 to 255 | dSP2 |
00E0 | 224 | 40103 | DSP3 (parameter mask designation) | 0 to 255 | dSP3 |
002D | 45 | 40104 | DSP4 (parameter mask designation) | 0 to 255 | dSP4 |
00D4 | 212 | 40105 | DSP5 (parameter mask designation) | 0 to 255 | dSP5 |
0001 | 1 | 40106 | DSP6 (parameter mask designation) | 0 to 255 | dSP6 |
0000 | 0 | 40107 | DSP7 (parameter mask designation) | 0 to 255 | dSP7 |
0000 | 0 | 40108 | DSP8 (parameter mask designation) | 0 to 255 | dSP8 |
0080 | 128 | 40109 | DSP9 (parameter mask designation) | 0 to 255 | dSP9 |
00FF | 255 | 40110 | DSP10 (parameter mask designation) | 0 to 255 | dSP10 |
00FF | 255 | 40111 | DSP11 (parameter mask designation) | 0 to 255 | dSP11 |
005F | 95 | 40112 | DSP12 (parameter mask designation) | 0 to 255 | dSP12 |
007C | 124 | 40113 | DSP13 (parameter mask designation) | 0 to 255 | dSP13 |