PID Parameters on 20050417T161717

BIT Parameters

HexDecimalCoilNameClear NameSet Name
0000010001Alarm1OffOn
0000010005Alarm2OffOn
0000010009Alarm1 OutputRelay OffRelay On
0000010010Alarm2 OutputRelay OffRelay On
0000010012HB Alarm OutputHB OffHB On
0000010013Alarm1 (same as 10001)OffOn
0000010014Alarm2 (same as 10002)OffOn
0000010016HB Alarm Output (same as 10012)HB OffHB On

Read Only Parameters (EU)

HexDecimalCoilNameDescriptionDisplay
02E474031001Process value (PV)0 to 10000 (0.00 to 100.00%FS
08CA225031002Currently used set value (SV)0 to 10000 (0.00 to 100.00%FS)
FA19-151131003Currently used deviation (DV)-10000 to 10000 (-100.00 to 100.00%FS)
283C1030031004MV (output 1)-300 to 10300 (-3.00 to 103.00%)OUT1
FED4-30031005MV (output 2)-300 to 10300 (-3.00 to 103.00%)OUT2
0001131006Station No.0 to 255STno
0000031007Alarm status(refer to Section 7.4.)
0000031008Input/main unit abnormal status(refer to Section 7.4.)
0000031009Ramp/soak current running position0 to 17 (refer to Section 7.4.)STAT
0000031010Heater current0 to 5000.0 to 50.0ACT
0000031011Timer 1 current count0 to 9999 (0 to 9999 sec)TM-1
0000031012Timer 2 current count0 to 9999 (0 to 9999 sec)TM-2
0000031015DI action status(refer to Section 7.4.)

Read/Write Parameters (EU)

HexDecimalCoilNameDescriptionDisplay
0000041001Non-volatile memory write-in
0000041002PID/FUZZY/SELF selection0:PID control,1:FUZZYcontrol,2:SELF tuning controlCTrL
08CA225041003SV value set on face panel0 to 10000
0000041004Control RUN/standby0: Invalidate standby (RUN),1:Validate standbySTby
0000041005Auto tuning commandAT
00375541006P0 to 9999 (0.0 to 999.9%)P
035A85841007I0 to 32000 (0 to 3200.0) seci
00A516541008D0 to 9999 (0.0 to 999.9) secD
000A1041009Hysteresis range at two-position control0 to 5000 (0.00 to 50.00%FS)HyS
000A1041010COOL0 to 1000 (0.0 to 100.0)CooL
0000041011Dead band-5000 to 5000 (-50.00 to +50.00)db
00FB25141012Anti-reset windup0 to 10000 (0.00 to 100.00%)Ar
0000041013Output convergence value-10000 to 10000 (-100.00 to 100.00%)bAL
0000041014PV shift-1000 to 1000 (-10.00 to 10.00%FS)PVOF
0000041015SV offset-5000 to 5000 (-50.00 to 50.00%FS)SVOF
0003341016Input type code0 to 16P-n2
0001141017Temperature unit0:degC 1:degFP-F
014032041018Input scale lower limit-1999 to 9999P-SL
1D60752041019Input scale upper limit-1999 to 9999P-SU
0001141020Decimal point place0 to 2P-dP
000A1041022Input filter time constant0 to 9000 (0.0 to 900.0 sec)P-dF
0001141023RCJ yes/no0: Disable RCJ,1: Enable RCJrCJ
0000041024MV limit kind0 to 15PCUT
FED4-30041025Output 1 lower limit-300 to 10300 (-3.00 to 103.00%)PLC1
283C1030041026Output 1 upper limit-300 to 10300 (-3.00 to 103.00%)PHC1
FED4-30041027Output 2 lower limit-300 to 10300 (-3.00 to 103.00%)PLC2
283C1030041028Output 2 upper limit-300 to 10300 (-3.00 to 103.00%)PHC2
014032041031Set value (SV) lower limit0 to 10000 (0.00 to 100.00%FS)SV-L
1D60752041032Set value (SV) upper limit0 to 10000 (0.00 to 100.00%FS)SV-H
0000041039Heater burnout alarm set value0 to 500(0.0 to 50.0A)Hb
0000041040Setting lock0 to 5LoC
000B1141041Alarm 1 type0 to 34ALM1
0000041042Alarm 2 type0 to 34ALM2
0005541044Alarm 1 set value or alarm 1 lower limit set valueAL1 or A1-L
0000041045Alarm 2 set value or alarm 2 lower limit set valueAL2 or A2-L
0005541047Alarm 1 upper limit set valueA1-H
0000041048Alarm 2 upper limit set valueA2-H
0000041050Alarm 1 hysteresis0 to 5000 (0.00 to 50.00%FS)A1hy
0000041051Alarm 2 hysteresis0 to 5000 (0.00 to 50.00%FS)A2hy
0000041053Alarm 1 ON-delay set value0 to 9999 (0 to 9999 sec)dLy1
0000041054Alarm 2 ON-delay set value0 to 9999 (0 to 9999 sec)dLy2
0BB8300041057Ramp/soak No. 1 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-1
014032041058Ramp/soak No. 2 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-2
014032041059Ramp/soak No. 3 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-3
014032041060Ramp/soak No. 4 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-4
014032041061Ramp/soak No. 5 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-5
014032041062Ramp/soak No. 6 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-6
014032041063Ramp/soak No. 7 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-7
014032041064Ramp/soak No. 8 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-8
0000041065Ramp/soak No. 1 ramp time0 to 59999 (0 to 5999min)TM1r
0000041066Ramp/soak No. 1 soak time0 to 5999 (0 to 5999 min)TM1S
0000041067Ramp/soak No. 2 ramp time0 to 5999 (0 to 5999 min)TM2r
0000041068Ramp/soak No. 2 soak time0 to 5999 (0 to 5999 min)TM2S
0000041069Ramp/soak No. 3 ramp time0 to 5999 (0 to 5999 min)TM3r
0000041070Ramp/soak No. 3 soak time0 to 5999 (0 to 5999 min)TM3S
0000041071Ramp/soak No. 4 ramp time0 to 5999 (0 to 5999 min)TM4r
0000041072Ramp/soak No. 4 soak time0 to 5999 (0 to 5999 min)TM4S
0000041073Ramp/soak No. 5 ramp time0 to 5999 (0 to 5999 min)TM5r
0000041074Ramp/soak No. 5 soak time0 to 5999 (0 to 5999 min)TM5S
0000041075Ramp/soak No. 6 ramp time0 to 5999 (0 to 5999 min)TM6r
0000041076Ramp/soak No. 6 soak time0 to 5999 (0 to 5999 min)TM6S
0000041077Ramp/soak No. 7 ramp time0 to 5999 (0 to 5999 min)TM7r
0000041078Ramp/soak No. 7 soak time0 to 5999 (0 to 5999 min)TM7S
0000041079Ramp/soak No. 8 ramp time0 to 5999 (0 to 5999 min)TM8r
0000041080Ramp/soak No. 8 soak time0 to 5999 (0 to 5999 min)TM8S
0000041081Ramp/soak mode0 to 15MOD
0000041082Ramp/soak commandProG
0000041083Ramp/soak pattern selectionPTn
008C14041085PV stable range0 to 10000(0.00 to 100.00%FS)SLFb
0000041087Communication DI action request(refer to section 7.4.)
0000041088Control action type code0 to 19P-n1
0001141089Output proportional cycle (output 1)0: Current output type,1 to 150(1 to 150 sec):Relay, SSR drive output typeTC
001E3041090Output proportional cycle (output 2)1 to 150(1 to 150 sec)TC2
0000041092Alarm 1 option function0 to 7 (binary data 000B to 111B)A1op
0000041093Alarm 2 option function0 to 7 (binary data 000B to 111B)A2op
0001141095DI1 action setting0 to 12di-1
0001141097Hysteresis mode setting0: off (main unit parameter setting) 1: on (main unit parameter setting)ONOF
0000041099User zero adjustment-5000 to 5000 (-50.00 to 50.00%FS)ADJ0
0000041100User span adjustment-5000 to 5000 (-50.00 to 50.00%FS)ADJS
00F424441101DSP1 (parameter mask designation)0 to 255dSP1
00FF25541102DSP2 (parameter mask designation)0 to 255dSP2
00E022441103DSP3 (parameter mask designation)0 to 255dSP3
002D4541104DSP4 (parameter mask designation)0 to 255dSP4
00D421241105DSP5 (parameter mask designation)0 to 255dSP5
0001141106DSP6 (parameter mask designation)0 to 255dSP6
0000041107DSP7 (parameter mask designation)0 to 255dSP7
0000041108DSP8 (parameter mask designation)0 to 255dSP8
008012841109DSP9 (parameter mask designation)0 to 255dSP9
00FF25541110DSP10 (parameter mask designation)0 to 255dSP10
00FF25541111DSP11 (parameter mask designation)0 to 255dSP11
005F9541112DSP12 (parameter mask designation)0 to 255dSP12
007C12441113DSP13 (parameter mask designation)0 to 255dSP13

Read Only Parameters (Raw)

HexDecimalCoilNameDescriptionDisplay
024658230001Process value (PV)0 to 10000 (0.00 to 100.00%FS
0A79268130002Currently used set value (SV)0 to 10000 (0.00 to 100.00%FS)
F7CC-210030003Currently used deviation (DV)-10000 to 10000 (-100.00 to 100.00%FS)
283C1030030004MV (output 1)-300 to 10300 (-3.00 to 103.00%)OUT1
FED4-30030005MV (output 2)-300 to 10300 (-3.00 to 103.00%)OUT2
0001130006Station No.0 to 255STno
0000030007Alarm status(refer to Section 7.4.)
0000030008Input/main unit abnormal status(refer to Section 7.4.)
0000030009Ramp/soak current running position0 to 17 (refer to Section 7.4.)STAT
0000030010Heater current0 to 5000.0 to 50.0ACT
0000030011Timer 1 current count0 to 9999 (0 to 9999 sec)TM-1
0000030012Timer 2 current count0 to 9999 (0 to 9999 sec)TM-2
0000030015DI action status(refer to Section 7.4.)

Read/Write Parameters (Raw)

HexDecimalCoilNameDescriptionDisplay
0000040001Non-volatile memory write-in
0000040002PID/FUZZY/SELF selection0:PID control,1:FUZZYcontrol,2:SELF tuning controlCTrL
0A79268140003SV value set on face panel0 to 10000
0000040004Control RUN/standby0: Invalidate standby (RUN),1:Validate standbySTby
0000040005Auto tuning commandAT
00375540006P0 to 9999 (0.0 to 999.9%)P
035A85840007I0 to 32000 (0 to 3200.0) seci
00A516540008D0 to 9999 (0.0 to 999.9) secD
000E1440009Hysteresis range at two-position control0 to 5000 (0.00 to 50.00%FS)HyS
000A1040010COOL0 to 1000 (0.0 to 100.0)CooL
0000040011Dead band-5000 to 5000 (-50.00 to +50.00)db
015D34940012Anti-reset windup0 to 10000 (0.00 to 100.00%)Ar
0000040013Output convergence value-10000 to 10000 (-100.00 to 100.00%)bAL
0000040014PV shift-1000 to 1000 (-10.00 to 10.00%FS)PVOF
0000040015SV offset-5000 to 5000 (-50.00 to 50.00%FS)SVOF
0003340016Input type code0 to 16P-n2
0001140017Temperature unit0:degC 1:degFP-F
014032040018Input scale lower limit-1999 to 9999P-SL
1D60752040019Input scale upper limit-1999 to 9999P-SU
0001140020Decimal point place0 to 2P-dP
000A1040022Input filter time constant0 to 9000 (0.0 to 900.0 sec)P-dF
0001140023RCJ yes/no0: Disable RCJ,1: Enable RCJrCJ
0000040024MV limit kind0 to 15PCUT
FED4-30040025Output 1 lower limit-300 to 10300 (-3.00 to 103.00%)PLC1
283C1030040026Output 1 upper limit-300 to 10300 (-3.00 to 103.00%)PHC1
FED4-30040027Output 2 lower limit-300 to 10300 (-3.00 to 103.00%)PLC2
283C1030040028Output 2 upper limit-300 to 10300 (-3.00 to 103.00%)PHC2
0000040031Set value (SV) lower limit0 to 10000 (0.00 to 100.00%FS)SV-L
27101000040032Set value (SV) upper limit0 to 10000 (0.00 to 100.00%FS)SV-H
0000040039Heater burnout alarm set value0 to 500(0.0 to 50.0A)Hb
0000040040Setting lock0 to 5LoC
000B1140041Alarm 1 type0 to 34ALM1
0000040042Alarm 2 type0 to 34ALM2
0007740044Alarm 1 set value or alarm 1 lower limit set valueAL1 or A1-L
FE44-44440045Alarm 2 set value or alarm 2 lower limit set valueAL2 or A2-L
0007740047Alarm 1 upper limit set valueA1-H
FE44-44440048Alarm 2 upper limit set valueA2-H
0000040050Alarm 1 hysteresis0 to 5000 (0.00 to 50.00%FS)A1hy
0000040051Alarm 2 hysteresis0 to 5000 (0.00 to 50.00%FS)A2hy
0000040053Alarm 1 ON-delay set value0 to 9999 (0 to 9999 sec)dLy1
0000040054Alarm 2 ON-delay set value0 to 9999 (0 to 9999 sec)dLy2
0E8A372240057Ramp/soak No. 1 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-1
0000040058Ramp/soak No. 2 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-2
0000040059Ramp/soak No. 3 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-3
0000040060Ramp/soak No. 4 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-4
0000040061Ramp/soak No. 5 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-5
0000040062Ramp/soak No. 6 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-6
0000040063Ramp/soak No. 7 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-7
0000040064Ramp/soak No. 8 target value0 to 10000 (0.00 to 100.00%FS, within set value limit)Sv-8
0000040065Ramp/soak No. 1 ramp time0 to 59999 (0 to 5999min)TM1r
0000040066Ramp/soak No. 1 soak time0 to 5999 (0 to 5999 min)TM1S
0000040067Ramp/soak No. 2 ramp time0 to 5999 (0 to 5999 min)TM2r
0000040068Ramp/soak No. 2 soak time0 to 5999 (0 to 5999 min)TM2S
0000040069Ramp/soak No. 3 ramp time0 to 5999 (0 to 5999 min)TM3r
0000040070Ramp/soak No. 3 soak time0 to 5999 (0 to 5999 min)TM3S
0000040071Ramp/soak No. 4 ramp time0 to 5999 (0 to 5999 min)TM4r
0000040072Ramp/soak No. 4 soak time0 to 5999 (0 to 5999 min)TM4S
0000040073Ramp/soak No. 5 ramp time0 to 5999 (0 to 5999 min)TM5r
0000040074Ramp/soak No. 5 soak time0 to 5999 (0 to 5999 min)TM5S
0000040075Ramp/soak No. 6 ramp time0 to 5999 (0 to 5999 min)TM6r
0000040076Ramp/soak No. 6 soak time0 to 5999 (0 to 5999 min)TM6S
0000040077Ramp/soak No. 7 ramp time0 to 5999 (0 to 5999 min)TM7r
0000040078Ramp/soak No. 7 soak time0 to 5999 (0 to 5999 min)TM7S
0000040079Ramp/soak No. 8 ramp time0 to 5999 (0 to 5999 min)TM8r
0000040080Ramp/soak No. 8 soak time0 to 5999 (0 to 5999 min)TM8S
0000040081Ramp/soak mode0 to 15MOD
0000040082Ramp/soak commandProG
0000040083Ramp/soak pattern selectionPTn
00C219440085PV stable range0 to 10000(0.00 to 100.00%FS)SLFb
0000040087Communication DI action request(refer to section 7.4.)
0000040088Control action type code0 to 19P-n1
0001140089Output proportional cycle (output 1)0: Current output type,1 to 150(1 to 150 sec):Relay, SSR drive output typeTC
001E3040090Output proportional cycle (output 2)1 to 150(1 to 150 sec)TC2
0000040092Alarm 1 option function0 to 7 (binary data 000B to 111B)A1op
0000040093Alarm 2 option function0 to 7 (binary data 000B to 111B)A2op
0001140095DI1 action setting0 to 12di-1
0001140097Hysteresis mode setting0: off (main unit parameter setting) 1: on (main unit parameter setting)ONOF
0000040099User zero adjustment-5000 to 5000 (-50.00 to 50.00%FS)ADJ0
0000040100User span adjustment-5000 to 5000 (-50.00 to 50.00%FS)ADJS
00F424440101DSP1 (parameter mask designation)0 to 255dSP1
00FF25540102DSP2 (parameter mask designation)0 to 255dSP2
00E022440103DSP3 (parameter mask designation)0 to 255dSP3
002D4540104DSP4 (parameter mask designation)0 to 255dSP4
00D421240105DSP5 (parameter mask designation)0 to 255dSP5
0001140106DSP6 (parameter mask designation)0 to 255dSP6
0000040107DSP7 (parameter mask designation)0 to 255dSP7
0000040108DSP8 (parameter mask designation)0 to 255dSP8
008012840109DSP9 (parameter mask designation)0 to 255dSP9
00FF25540110DSP10 (parameter mask designation)0 to 255dSP10
00FF25540111DSP11 (parameter mask designation)0 to 255dSP11
005F9540112DSP12 (parameter mask designation)0 to 255dSP12
007C12440113DSP13 (parameter mask designation)0 to 255dSP13

Main Coffee Page


Last Updated: 04/17/05
Dave Bennett (dave at vogie.com)