PID Parameters on 04/25/2005, at 21:21:39

Read Only Parameters (EU)

HexDecimalCoilNameDescriptionDisplay
02D072031001Process value (PV) -1999 to 9999 (within input scale)
08CA225031002Currently used set value (SV) -1999 to 9999 (within set Value Limit)
FA05-153131003Currently used deviation (DV) -1999 to 9999 (-100 to 100% value of input scale)
283C1030031004MV (output 1) -300 to 10300 (-3.00 to 103.00%)OUT1
0000031007Alarm status (refer to Section 7.4.)

Read/Write Parameters (EU)

HexDecimalCoilNameDescriptionDisplay
0000041002PID/FUZZY/SELF selection 0:PID control
1:FUZZYcontrol
2:SELF tuning control
CTrL
08CA225041003SV value set on face panel -1999 to 9999 (within set value limits)
0000041004Control RUN/standby 0: Invalidate standby (RUN)
1:Validate standby
STby
0000041005Auto tuning command 0: Autotuning disabled
1: Standard type AT
2: Low PV Type AT
AT
00375541006P 0 to 9999 (0.0 to 999.9%)P
035A85841007I 0 to 32000 (0 to 3200.0) seci
00A516541008D 0 to 9999 (0.0 to 999.9) secD
000A1041009Hysteresis range at two-position control 0 to 9999 (0 to 50% value of input scale)HyS
000A1041010COOL 0 to 1000 (0.0 to 100.0)CooL
0000041011Dead band -5000 to 5000 (-50.00 to +50.00)db
00FB25141012Anti-reset windup -1999 to 9999 (0 10 100% value of input scale)Ar
0000041013Output convergence value -10000 to 10000 (-100.00 to 100.00%)bAL
0000041014PV shift -1999 to 9999 (-10 to 10% value of input scale)PVOF
0000041015SV offset -1999 to 9999 (-50 to 50% value of input scale)SVOF
0003341016Input type code 0 to 16P-n2
0001141017Temperature unit 0:degC 1:degFP-F
014032041018Input scale lower limit -1999 to 9999P-SL
1D60752041019Input scale upper limit P-SU
0001141020Decimal point place 0 to 2P-dP
000A1041022Input filter time constant 0 to 9000 (0.0 to 900.0 sec)P-dF
0001141023RCJ yes/no 0: Disable RCJ
1: Enable RCJ (perform reference cold junction compensation)
rCJ
000B1141041Alarm 1 type 0 to 34ALM1
00182441042Alarm 2 type ALM2
0005541044Alarm 1 set value or alarm 1 lower limit set value -1999 to 9999 For absolute value alarm: 0 to 100.00% value of input scale For deviation alarm: -100 to 100% value of input scaleAL1 or A1-L
0B54290041045Alarm 2 set value or alarm 2 lower limit set value AL2 or A2-L
0000041047Alarm 1 upper limit set value A1-H
0FA0400041048Alarm 2 upper limit set value A2-H
0000041050Alarm 1 hysteresis 0 to 9999 (0 to 50% value of input scale)A1hy
0000041051Alarm 2 hysteresis A2hy
0000041053Alarm 1 ON-delay set value 0 to 9999 (0 to 9999 sec)dLy1
0000041054Alarm 2 ON-delay set value dLy2
0BB8300041057Set Value 2 Used with DI switch -1999 to 9999Sv-1
008C14041085PV stable range -1999 to 9999 (within input scale)SLFb
000A1041089Output proportional cycle (output 1) 0: Current output type,1 to 150(1 to 150 sec):Relay, SSR drive output typeTC